OVSRSEL=X2, WARMUPMODE=NORMAL, CHCONREFWARMIDLE=PREFSCAN, PRESC=NODIVISION
Control Register
WARMUPMODE | Warm-up Mode 0 (NORMAL): ADC is shut down after each conversion. 5us warmup time is used before each conversion. 1 (KEEPINSTANDBY): ADC is kept in standby mode between conversions. 1us warmup time is used before each conversion. 2 (KEEPINSLOWACC): ADC is kept in slow acquisition mode between conversions. 1us warmup time is used before each conversion. 3 (KEEPADCWARM): ADC is kept on after conversions, allowing for continuous conversion. |
SINGLEDMAWU | SINGLEFIFO DMA Wakeup |
SCANDMAWU | SCANFIFO DMA Wakeup |
TAILGATE | Conversion Tailgating |
ASYNCCLKEN | Selects ASYNC CLK Enable Mode When ADCCLKMODE=1 |
ADCCLKMODE | ADC Clock Mode |
PRESC | Prescalar Setting for ADC Sample and Conversion Clock 0 (NODIVISION): undefined |
TIMEBASE | 1us Time Base |
OVSRSEL | Oversample Rate Select 0 (X2): 2 samples for each conversion result 1 (X4): 4 samples for each conversion result 2 (X8): 8 samples for each conversion result 3 (X16): 16 samples for each conversion result 4 (X32): 32 samples for each conversion result 5 (X64): 64 samples for each conversion result 6 (X128): 128 samples for each conversion result 7 (X256): 256 samples for each conversion result 8 (X512): 512 samples for each conversion result 9 (X1024): 1024 samples for each conversion result 10 (X2048): 2048 samples for each conversion result 11 (X4096): 4096 samples for each conversion result |
DBGHALT | Debug Mode Halt Enable |
CHCONMODE | Channel Connect |
CHCONREFWARMIDLE | Channel Connect and Reference Warm Sel When ADC is IDLE 0 (PREFSCAN): Keep scan reference warm and APORT switches for first scan channel closed if WARMUPMODE is not NORMAL 1 (PREFSINGLE): Keep single reference warm and keep APORT switches for single channel closed if WARMUPMODE is not NORMAL 2 (KEEPPREV): Keep last used reference warm and keep APORT switches for corresponding channel closed if WARMUPMODE is not NORMAL |